EV210-0004G-S2: Kompakter Hochleistungs-Vektor-VFD | 0,4kW, 220V

Model:EV210-0004G-S2
Leistung:0,4 kW (0,5HP)
Eingangsleistung: Einphasig 220 V (±10%)
Leistung:1.0kVA
Eingangsstrom:5,4A
Ausgangsstrom:2,3A
The EV210-0004G-S2 is a high-performance miniature inverter engineered for applications demanding precision motor control in limited installation spaces. It solves a critical engineering challenge: delivering high-performance, responsive current vector control in an ultra-compact chassis.This 0.4kW VFD (0.5HP) is the perfect solution for powering small three-phase asynchronous motors from a standard 220V single-phase supply. Unlike entry-level mini drives that offer only basic V/F control, the EV210-0004G-S2 provides advanced sensorless vector control (SVC) , ensuring precise speed regulation and superior torque, even under fluctuating loads. Its design makes it the premier AC motor speed controller for complex, small-scale automated machinery.

Why Choose This 0.4kW (0.5HP) 220V Compact Vector VFD?

Choosing the right drive is critical. This specific 0.4kW (0.5HP) VFD  is the ideal solution when your application is too demanding for a basic mini-drive, but the installation space is too small for a full-sized vector drive.   

  1. The “Compact Vector” Hybrid Advantage: This is the perfect hybrid drive. When a basic miniature AC drive (like the EV200, designed for “simple speed regulation” ) lacks the precision for your load, the EV210-0004G-S2 provides the advanced vector control  you need in the compact form factor you want.   
  2. Precision for Complex Micro-Machinery: This AC motor speed controller excels in applications beyond simple fans. Its vector control is essential for Werkzeugmaschinen , Textilaufwickler , oder Verpackungsmaschinen  bei denen der Motor eine exakte Drehzahl und ein genaues Drehmoment unter wechselnden Lasten beibehalten muss.   
  3. Quiet, Reliable Operation: The adjustable carrier frequency provides low noise operation , a critical feature for equipment installed in noise-sensitive environments like laboratories or small workshops.   
  4. Cost-Effective Automation: By integrating PID and RS485 communication , this compact vector VFD can simplify your system design, eliminating the need for external controllers and reducing total system cost and complexity. 

Typische Anwendungsbereiche

  • A compact textile winder, controlled by a 0.4kW miniature vector VFD, ensures precise thread tension and speed.

    Textilmaschinen

    A perfect textile machine VFD for small winders, spinning frames, and knitting machines requiring precise tension and speed synchronization in a compact form factor.

  • Ein CNC-Maschinen-VFD, der eine präzise und leistungsstarke Motorsteuerung für die Spindel einer Fräsmaschine bietet.

    CNC & Machine Tools

    Provides the precise sensorless vector control needed for CNC engraving spindles, small machine tools , grinders, and lathes that require stable torque across their speed range.

  • Laboratory & Medical

    Its low noise operation and precision make it suitable for medical centrifuges or advanced laboratory mixers and samplers.

Merkmale der Kontrolle

Kontrollmodus

Leistungsstarke Stromvektorregelung, sensorlose Vektorregelung (SVC), V/F-Regelung

Höchste Frequenz

Vektorsteuerung: 0~500Hz; V/F-Steuerung: 0~500Hz 

Trägerfrequenz

0.5KHz ~ 16.0KHz (einstellbar, für geräuscharmen Betrieb)

Verfolgung der Geschwindigkeit

Merkmale “Geschwindigkeitsnachführung Geschwindigkeitsneustartfunktion” 

Gleichstrombremsung

Startfrequenz: 0.00 ~ Max Freq; Bremszeit: 0.0 ~ 100.0s 

Beschleunigungs-/Abbremszeit

0,0s ~ 6500,0s 

E/A-Spezifikationen

Analoger Eingang

1 Kanal (0~10V / 0~20mA)

Analoger Ausgang

1 Kanal (0~10V / 0~20mA) 

Digitaler Ausgang

1 programmierbarer Relaisausgang (TA, TC) 

Kommunikation

Standard RS-485 (Modbus) 

Betriebsumgebung

Aufstellungsort

In Innenräumen, kein direktes Sonnenlicht, kein Staub, keine korrosiven Gase usw.

Höhenlage

Weniger als 1000 Meter

Temperatur in der Umgebung

-10°C bis +40°C 

Luftfeuchtigkeit

<95%RH, keine Kondensation

Strukturelle Abmessungen

Abmessungen (B x T x H)

72 x 105 x 146 mm

Einbaumaße (A x B)

63,0 x 136,5 mm

Einbauloch

φ2.3

Qualitätssicherung

Dieses Produkt wird von Nanjing Oulu Electric Corp. entwickelt und hergestellt. Als nationales Hightech-Unternehmen mit den Schwerpunkten Industrieautomation und neue Energien verfügen wir über ein erfahrenes Forschungs- und Entwicklungsteam und fortschrittliche Produktionsanlagen, um unseren Kunden weltweit hochwertige und zuverlässige Produkte und Lösungen zu bieten.

Häufig gestellte Fragen (FAQ)

1. What is the main difference between the 0.4kW EV210 and the 0.4kW EV200 VFD?

The key difference is the control method and positioning. The EV200 is a “small inverter” designed for einfache Drehzahlregelung. The EV210 is a “high-performance miniature inverter”  that integrates advanced current vector control. Choose the EV200 for simple applications like small fans or basic conveyors. Choose the EV210 for applications needing precise speed, high starting torque, or stable control under load, such as machine tools or packaging.   

2. Can I use this 0.4kW VFD for a CNC or machine tool spindle motor?

Yes, the EV210-0004G-S2 is an excellent choice for small machine tool  spindles. Its sensorless vector control  provides stable torque even at low speeds, which is crucial for cutting. Furthermore, its adjustable high-carrier frequency (up to 16.0KHz)  ensures low noise operation , reducing the “whine” from the motor.   

3. What is the benefit of the ‘speed tracking restart’ function?

This function  allows the VFD to smoothly “catch” a motor that is already spinning (e.g., a fan coasting after a brief power outage) and return it to the set speed without a harsh start or tripping on overcurrent. This is critical for reliable, uninterrupted operation in automated systems.   

4. How does the built-in PID controller work?

The built-in PID  allows the VFD to automatically regulate motor speed to maintain a process variable. For example, you can connect a pressure sensor (as an analog input) and set a target pressure. The VFD will then speed up or slow down a small pump  to perfectly maintain that pressure, all without needing an external PLC.   

 

Schnellstart-Anleitung (How-To)

Warnung: Die folgenden Schritte sind nur eine grundlegende Anleitung. Alle elektrischen Arbeiten müssen von qualifiziertem Fachpersonal durchgeführt werden. Stellen Sie vor der Verdrahtung sicher, dass die Hauptstromversorgung vollständig unterbrochen ist, und warten Sie mindestens 10 Minuten, damit sich die internen Kondensatoren des VFD vollständig entladen können.   

Schritt 1: Installation

Mount the VFD vertically on a sturdy, non-flammable surface (like a metal backplate) or a DIN rail in a well-ventilated cabinet. Ensure sufficient clearance for airflow. The compact 72mm width  allows for high-density, side-by-side installation.   

Schritt 2: Verdrahtung des Hauptstromkreises

  • Schließen Sie Ihre einphasigen 220-V-Wechselstromleitungen an die Eingangsklemmen S/L1 und T/L2 des Wechselrichters an.   
  • Connect the three wires of your 0.4kW (0.5HP) three-phase asynchronous motor to the inverter’s output terminals U, V, and W.   
  • Schließen Sie das Erdungskabel sicher an den PE-Anschluss (Schutzerde) des Wechselrichters an.   

Schritt 3: Verdrahtung des Steuerkreises (für einfachen 2-Draht-Start/Stopp)

  • Schließen Sie ein Ende eines externen Schalters (oder einer Taste) an die digitale Eingangsklemme X1 an.   
  • Verbinden Sie das andere Ende des Schalters mit dem gemeinsamen Anschluss COM.   
  • (This setup uses X1 for a simple “Run” command in 2-wire mode).

Schritt 4: Einstellung und Konfiguration der Motorparameter

  • Stellen Sie beim ersten Einschalten die VFD-Parameter so ein, dass sie mit dem Typenschild Ihres Motors übereinstimmen:   
    • Set P1-01 (Motor Rated Power) to 0.4 (kW).
    • P1-02 (Motornennspannung) auf 220 (V) einstellen.
    • Stellen Sie P1-03 (Motornennstrom) entsprechend dem Typenschild Ihres Motors ein.
    • P1-04 (Motornennfrequenz) einstellen (z. B. 50 oder 60 Hz).
    • P1-05 (Motornenndrehzahl) einstellen (z. B. 1440, 2800 usw.).
  • Um den 2-Draht-Start/Stopp ab Schritt 3 zu aktivieren:
    • Set P0-02 (Command source) to “1” (Terminal command channel).   
    • Set P4-00 (X1 function selection) to “1” (Forward run).   
  • For optimal vector control performance, perform a motor auto-tune (set P1-37, see manual for details).   

Schritt 5: Testlauf

Schalten Sie nach der Überprüfung aller Kabel und Einstellungen die Hauptstromversorgung ein. Schließen Sie den externen Schalter, der zwischen X1 und COM angeschlossen ist. Der Motor sollte starten und in Vorwärtsrichtung laufen. Öffnen Sie den Schalter, und der Motor verlangsamt sich und bleibt stehen.

Hauptmerkmale und Vorteile

    • Advanced Vector Control in a Miniature Body: This drive integrates a high-performance current vector inverter  into a compact frame. It provides outstanding torque characteristics and precise speed control (SVC), far superior to standard V/F control , making it ideal for dynamic loads.   
    • Ultra-Compact, Space-Saving Design: Measuring only 72mm wide and 105mm deep , this miniature vector VFD is designed for high-density DIN-rail mounting in crowded control cabinets, saving space and reducing overall machine footprint.   
    • Quiet & Stable Performance: Engineered for low noise operation, the VFD features an adjustable carrier frequency (0.5KHz ~ 16.0KHz)  to minimize high-frequency motor noise, making it suitable for laboratory or light commercial environments. The Automatic Voltage Control (AVR) function  ensures stable performance even with grid fluctuations.   
    • Integrated PID & PLC Functions: Features a built-in PID controller  and Easy PLC function, enabling simple closed-loop process control (e.g., managing pressure, flow) and basic multi-segment speed operation.   
    • Reliable System Protection: Offers comprehensive protection functions , including overcurrent, overvoltage, undervoltage, overheat, and overload. Includes a speed tracking restart function  for a smooth, safe recovery from a momentary power loss.   
    • Flexible System Integration: Standard built-in RS485 communication (Modbus protocol)  allows this 0.4kW VFD  to be easily integrated into larger automation systems. Flexible I/O includes analog inputs (0-10V/0-20mA) and a programmable relay output.   

     

Datei

Größe

Aktion

VFD-Auswahlhilfe.pdf

4.2MB

VFD EV210 Benutzerhandbuch.pdf

1,3MB

Ähnliche Produkte