EV510A-0004G-S2: Single Phase Vector VFD | 0.4kW, 220V

Model:EV510A-0004G-S2
Power:0.4 kW (0.5HP)
Potencia de entrada: 220 V monofásica (±15%)
Power Capacity:1.0kVA
Input Current:5.4A
Output Current:2.3A
The EV510A-0004G-S2 is a high-performance vector VFD specifically engineered for industrial automation applications that demand high precision but have lower power requirements. As part of the technologically advanced EV510A series, this AC motor drive is a comprehensive upgrade to the EV510 series, featuring a more compact design, superior load capacity, and more stable performance. This model, an ideal 0.4 kW VFD, utilizes a unique current vector control algorithm to efficiently drive small-power asynchronous and synchronous motors, providing a cost-effective ideal drive core for all types of precision machinery.

Why Choose This 0.4 kW (0.5HP) 220V Single Phase Vector VFD?

Choosing the right drive is crucial for performance and reliability. This specific 0.4 kW (0.5HP) VFD is the ideal solution when your application requires more than just basic speed control.

  • Precision in a Small Package: While many small VFDs only offer simple V/F control, this model provides advanced vector control. This is essential for applications needing stable speed under varying loads, high starting torque for demanding machinery, and overall smoother, more precise motor performance.   
  • Energy and Cost Efficiency: By precisely matching the motor’s speed to the application’s demand, this VFD significantly reduces energy consumption compared to running a motor at full speed, leading to lower operational costs. The integrated features, like the built-in PLC and PID controller, can also eliminate the need for external control components, saving on hardware costs and simplifying your system design.   
  • Mayor vida útil de los equipos: Las capacidades de arranque y parada suaves reducen la tensión mecánica en motores, cajas de engranajes y correas. Esta aceleración gradual minimiza el desgaste, prolongando la vida útil de toda la maquinaria y reduciendo las necesidades de mantenimiento.   
  • Versatility for Complex Applications: With a rich set of I/O terminals and standard Modbus communication, this drive is built for integration. It’s perfect for creating smart, automated systems for conveyors, pumps, and specialized machinery where feedback and external control are necessary.

Campos de aplicación típicos

  • An automated labeling machine precisely applying labels to bottles on a fast-moving conveyor, demonstrating high-speed packaging machine VFD control.

    Light Packaging & Labeling Equipment

    An excellent choice for a packaging machine VFD or for automatic labeling machine motor control systems.

  • Una centrífuga médica que funciona sin problemas en un laboratorio de alta tecnología, impulsada por un sistema de control de motor de precisión para un funcionamiento estable y silencioso.

    Laboratory & Medical Equipment

    Used for analytical instrument stirrers and medical centrifuge VFD applications that require smooth, vibration-free laboratory equipment motor control.

  • A precision robotic arm in an electronics manufacturing line, with its conveyor belt speed managed by a compact VFD for accurate component placement.

    Electronics Manufacturing

    For small assembly lines, plug-in machines, and other precision equipment.

Características de control

Modo de control

Control vectorial sin sensores (SVC), Control vectorial en bucle cerrado (FVC), Control V/F 

Frecuencia más alta

Control vectorial: 0~500Hz; Control V/F: 0~500Hz

Par de arranque

0,5Hz / 150% (en modo SVC)

Velocidad

1:100 (SVC)

Velocidad Precisión

±0,5% (SVC)

Capacidad de sobrecarga

150% corriente nominal durante 60s; 180% corriente nominal durante 3s

Especificaciones de E/S

Entrada digital

7 canales, 1 de ellos con entrada de impulsos de alta velocidad de hasta 100 kHz

Entrada analógica

2 canales, con entrada de tensión de 0~10 V o de corriente de 0~20 mA

Salida digital/de impulsos

1 canal de salida de impulsos de alta velocidad (0~100 kHz)

Salida de relé

2 canales de salida de relé

Salida analógica

2 canales, con salida de corriente de 0~20 mA o tensión de 0~10 V

Comunicación

RS-485 estándar (Modbus), compatible con CANlink

Entorno operativo

Lugar de instalación

En interiores, sin luz solar directa, sin polvo, gases corrosivos, etc.

Altitud

Por debajo de 1000 metros

Temperatura ambiente

De -10°C a +40°C (reducción necesaria para 40~50°C) 

Humedad

<95%RH, sin condensación

Dimensiones estructurales

Dimensiones (An x Pr x Al)

112 x 118 x 180 mm

Tamaño de la instalación (A x B)

101 x 171 mm

Agujero de instalación

φ4.6

Peso

1,3 kg

Garantía de calidad

Este producto ha sido desarrollado y fabricado por Nanjing Oulu Electric Corp. Como empresa nacional de alta tecnología centrada en la automatización industrial y las nuevas energías, contamos con un experimentado equipo de I+D e instalaciones de producción avanzadas, dedicados a ofrecer productos y soluciones fiables y de alta calidad a clientes de todo el mundo.

Preguntas más frecuentes (FAQ)

1. ¿Cuál es la diferencia entre el control V/F y el control vectorial sin sensores (SVC)?

El control V/F es un método básico de regulación de la velocidad del motor, adecuado para cargas de uso general, como ventiladores y bombas, en las que el control preciso del par no es crítico. El control vectorial sin sensor (SVC) es un algoritmo más avanzado que proporciona un control preciso del par del motor sin necesidad de encoder. Proporciona un par de arranque superior a bajas velocidades y una mayor estabilidad de la velocidad, por lo que es ideal para equipos más exigentes.   

2. ¿Cómo puedo seleccionar el modelo de variador de frecuencia adecuado para mi motor?

The selection of a VFD primarily depends on three core parameters: the motor’s rated power, rated voltage, and the application’s load type. For example, in the model EV510A-0004G-S2, “0004” indicates it’s for a 0.4kW motor, “G” stands for general-purpose load (suitable for constant torque applications), and “S2” signifies a single-phase 220V input. Always ensure the VFD’s rated current is greater than or equal to the motor’s rated current.   

3. ¿Cuáles son los requisitos del entorno de instalación del inversor?

Para garantizar un funcionamiento estable y una larga vida útil, el inversor debe instalarse en el interior, en una zona bien ventilada y alejada de la luz solar directa. La temperatura ambiente debe estar comprendida entre -10°C y +40°C, con una humedad inferior a 95%RH y sin condensación. La altitud de instalación debe ser inferior a 1000 metros, y la zona debe estar libre de polvo, gases corrosivos y materiales inflamables.   

4. ¿Qué ocurre si se produce un corte momentáneo de electricidad?

Esta serie de variadores incorpora una función “ride-through” (parada instantánea, no paro). En caso de una breve caída de tensión de la red eléctrica o un corte momentáneo, el variador de frecuencia puede utilizar la energía realimentada por el motor para compensar la pérdida de tensión, lo que le permite seguir funcionando durante un breve periodo y evitar interrupciones de la producción.

Guía de inicio rápido (How-To)

Advertencia: Los siguientes pasos son sólo una guía básica. Todos los trabajos eléctricos deben ser realizados por personal profesional cualificado. Antes de realizar cualquier cableado, asegúrese de que la alimentación principal está completamente desconectada y espere al menos 10 minutos para que los condensadores internos del variador de frecuencia se descarguen por completo.   

Paso 1: Instalación

Monte el inversor verticalmente sobre una superficie resistente y no inflamable, como una placa de montaje metálica. Asegúrese de que haya suficiente espacio libre alrededor de la unidad (se recomienda al menos 100 mm) para una ventilación y disipación del calor adecuadas.   

Paso 2: Cableado del circuito principal

  1. Conecte las líneas de alimentación monofásicas de 220 V CA a los bornes de entrada del inversor. R y S (L1/L2).
  2. Conecte los tres cables del motor asíncrono trifásico a los bornes de salida del variador. UV, y W.
  3. Conecte firmemente el cable de tierra al inversor. PE (tierra de protección).   

Paso 3: Cableado del circuito de control (para arranque/parada básicos)

  1. Conecte un extremo de un interruptor externo (o botón) al terminal de entrada digital S1.
  2. Conecta el otro extremo del interruptor al terminal común COM.
  3. Establecer parámetro P0-02 (Selección de la fuente de comandos) a “1” (Canal de comandos del terminal).   
  4. Establecer parámetro P4-00 (Selección de función S1) a “1” (Marcha adelante).   

Paso 4: Ajuste de los parámetros del motor y autoajuste

  1. En el primer encendido, introduzca con precisión los siguientes parámetros de la placa de características de su motor:
    • P1-01: Motor Rated Power (set to 0.4kW)    
    • P1-02: Tensión nominal del motor (ajustada a 220V)    
    • P1-03: Corriente nominal del motor    
    • P1-04: Frecuencia nominal del motor    
    • P1-05: Velocidad nominal del motor    
  2. Para un rendimiento óptimo del control vectorial, realice un autoajuste del motor. Ajuste el parámetro P1-37 (método de autoajuste del motor) a “2” (autoajuste dinámico) y ponga en marcha el variador.   

Paso 5: Prueba de funcionamiento

Después de confirmar que todo el cableado y los ajustes de los parámetros son correctos, conecte la alimentación principal. Cierre el interruptor externo conectado entre S1 y COM. El motor debe empezar a girar en dirección de avance. Abra el interruptor y el motor se detendrá de acuerdo con el tiempo de deceleración establecido.

Principales características y ventajas

  • Precise Low-Speed Control Performance: Employs advanced sensorless vector control (SVC) technology to achieve smooth and precise motor control even under light loads, providing up to 150% starting torque at just 0.5Hz for low-speed high-torque applications.   
  • Sufficient Safety Margin: Designed for general-purpose (G-type) loads, it can withstand 150% of the rated current for 60 seconds and 180% for 3 seconds, providing ample safety protection for small vector control VFD applications against unexpected load fluctuations.   
  • Highly Integrated Control Functions: Features a built-in PLC, multi-speed operation, and VFD with PID control, allowing engineers to implement more complex automation sequences without an external controller, which is especially suitable for space and cost-sensitive applications.   
  • Protección integral del sistema: Proporciona múltiples funciones de protección, incluyendo sobrecorriente, sobretensión, subtensión, sobrecalentamiento, sobrecarga y pérdida de fase de salida, con detección de cortocircuito del motor al encendido para garantizar un funcionamiento seguro y fiable.   
  • Flexible I/O Configuration: Standard on this single-phase 220V VFD are 7 digital inputs (including one high-speed pulse), 2 analog inputs, 2 relay outputs, and 2 analog outputs, offering powerful expansion capabilities for connecting sensors and actuators, including Modbus RS485 VFD communication.   
  • Diseño compacto y eficiente: Su diseño estructural optimizado lo hace más pequeño que la generación anterior, con un peso de sólo 1,3 kg, lo que ahorra espacio de instalación y facilita su integración en equipos compactos. 

Archivo

Talla

Acción

Guía de selección de VFD.pdf

4,2 MB

VFD EV510A Manual de Usuario.pdf

1,8 MB